Part Number Hot Search : 
74HC1G1 NL644 BFR181 SFH9250L 13BCA Q6004V4 PR2001G NTE63
Product Description
Full Text Search
 

To Download TA105 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Very low electrical noise 25W continuous/50W peak 5Khz bandwidth Integral forced-air cooling Digital on-the-fly gain control (DTS) Over temperature protection Selectable current limit
Applications
voice coil motors x-y micro stages metrology tools small DC motors
A robust linear amplifier, built to provide quiet and smooth power to brush motors. The TA105 is a linear servo motor amplifier, designed to drive a brush motor with up to 50W of power. The TA105 is an excellent solution for voice-coil type motors, high-precision positioning applications, and systems requiring ultra-quiet driving power, when low-noise operation is essential. Trust Automation's Dynamic Transconductance Selection (DTS) feature allows changing the amplifier's torque gain on-the-fly thus permitting high-resolution control, without sacrificing power capability. DTS is included on all of Trust Automation's amplifiers. The TA105 can be operated in voltage (velocity) mode or current (torque) mode; selected via a user-accessible DIP switch. Fault logic is also selectable via a DIP switch. Trust Automation is committed to products that are easy to install and use. Amplifier connections are made via pluggable-terminal connectors. Therefore, all connections are easily installed and removed, which reduces hardware cost, and assembly time.
205 Suburban Road x San Luis Obispo, CA 93401 Phone: (805) 544-0761 x Fax: (805) 544-4621 www.TrustAutomation.com
Connector Pinouts
Connector - J1
Wago P/N 733-110
Connector - J2
Wago P/N 734-105
Pin
1 2 3 4 5 6 7 8 9 10
Description
Pin
Description
1 Motor + Command Signal Input A+ 2 Motor Command Signal Input A3 GND Aux Gnd 4 GND Aux Gnd 5 VSUPPLY (15-48VDC) Dynamic Transconductance Select Bit D0 Dynamic Transconductance Select Bit D1 /ENABLE* *Referenced to Aux Gnd FAULT* **User-supplied/connected for optical isolation (optional) Aux Gnd ***Referenced to GND VAUX (user-supplied +5V)**
Switch Settings
S1 - System Configuration SW# DOWN
1 2 3 4 5 6 TA105-supplied +5V (20mA max) Aux Gnd tied to GND /FAULT Current mode DTS bit 0 DTS bit 1
UP
User-supplied +5V (for optical isolation) Aux Gnd isolated from GND FAULT Voltage mode (Av=20)
Gain - Transconductance & DTS Setting S1-5 S1-6
10V 10V 10V 10V in in in in = = = = 0.5A 1.0A 1.5A 2.0A out out out out Down Up Down Up (0) (1) (0) (1) Down Down Up Up (0) (0) (1) (1)
NOTE:
S1-5, S1-6 are shown UP.
S1-5 and S1-6 must be "UP" for DTS use.
123456
6 5 4 3 2 1
Electrical
Supply Voltage Equivalent Motor Voltage Output Current Fault /Enable Command Input Torque Gain Bandwidth
______ *dependent upon motor load **for 0.5 second ***into a 2.5 mH load
Mechanical
15-48V up to 43V* 2A peak** TTL Level 0 or 1 TTL Level 0 10V 0.05-0.2A/V 5KHz*** Length Width Height Weight Mounting 5.5 inches (allow >1 inch clearance on each end for sufficient forced-air cooling) 2.2 inches 2.1 inches 20 ounces (4) 6-32 screws
Absolute Maximum Ratings
Supply Voltage Command Input Heatsink Temperature 52V 12V 75 oC
Heat Dissipation - continuous 30W - peak 50W
205 Suburban Road x San Luis Obispo, CA 93401 Phone: (805) 544-0761 x Fax: (805) 544-4621 www.TrustAutomation.com
Rev. C (04/00)


▲Up To Search▲   

 